Show: 25 50 75 100 Results

Search results: 25 out of 140

مقاومه كسر القشور الخزفية المصنوعة من نوعين من السيراميك بوجود وعدم وجود الحشوة الراتنجية == Fracture resistance of two porcelain laminated veneer materials with and without CL V composite restoration (A comparative in vitro study)

Author name: اسراء محمد سعيد الدولعي
Supervisor name: عمار عطا الله السعدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

تاثير التدوير الحراري على قوة الارتباط القصي للخزف المفخور على سطح التيتانيوم النقي و سبيكة النيكل/كروم باستعمال فحص الارتباط القصي : دراسة مختبرية == Effect of Thermal Cycling on Shear Bond Strength of Porcelain Fused to Titanium and Ni/Cr Alloy Using Shear Test (In Vitro Study)

Author name: سنان سامي البناء
Supervisor name: هيثم جاسم العزاوي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
University: University of Baghdad
Language: English
University location: Baghdad
First pages:

كفاءة التنظيف لمبرد XP - endo Finisher بالمقارنة مع انظمة الارواء بالتردد الصوتي والتردد فوق الصوتي : دراسة خارج الجسم == Cleaning Efficiency of Xp - Endo Finisher File In Comparison With Sonic And Ultrasonic Irrigation Systems (An In Vitro Study)

Author name: مهند غازي عزاوي
Supervisor name: جمال عزيز مهدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:
Abstract: This in vitro study was conducted to evaluate and compare the efficiency of XP - endo Finisher, EndoActivator sonic irrigation system and the NSK Varios ultrasonic irrigation system in removing dentin debris at three levels of root canals and to compare the percentage of dentin debris among the three levels for each irrigation system. Sixty freshly extracted upper molar teeth with straight palatal root canals were used in this study. All canals were prepared with ProTaper NEXT rotary files to size X4, 1mm from the anatomic apex with irrigation of 1 ml 2.0% NaOCl between the files. After that the samples were randomly distributed into three groups of twenty samples each, irrigated with 1 ml 2.0% NaOCl, followed by irrigant activation for 60 seconds with three different irrigation systems; group one, by using the XP - endo Finisher; group two, by sonic irrigation using the EndoActivator system; and group three, by ultrasonic irrigation using the NSK Varios, then all the groups received a final rinse of 5 ml 2.0% NaOCl. After the final rinse, the roots were split longitudinally into two parts and photographed with a professional digital camera. The digital images were then transferred into a computer and opened in Adobe Photoshop CC 2015 software and the canal was magnified 200x. The percentage of dentin debris remaining at the apical level (0 - 3mm), the middle level (3 - 6mm) and the coronal level (6 - 9mm) was calculated by dividing the number of pixels occupied by the dentin debris at each level by the number of pixels representing the entire canal area. Data were analyzed statistically by ANOVA and LSD at 1% and 5% significant levels. This study showed that cleaning the canal with the XP - endo Finisher or NSK Varios ultrasonic irrigation system resulted in significantly cleaner canals (P<0.01) than the EndoActivator sonic activation system at all canal levels. The XP - endo Finisher resulted in cleaner canals than the NSK Varios ultrasonic irrigation system at all levels, but the difference is not statistically significant (P>0.05). The apical level of all the canals showed a greater amount of dentin debris (P<0.01) compared to the middle and coronal levels, regardless of the irrigation device used.

تحليل القوى المستقرة لثلاثة انواع مختلفة من المواد الراتنجية بطريقة عملية وعددية == Static Stress Analysis For Three Different Types of Composite Materials Experimentally And Numerically

Author name: محمد وائل سعيد
Supervisor name: حكمت عبد الرحيم الغراوي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:
Abstract: t is important to analyze and compare the stresses induced in different composite material types during load application to know which type of composite will behave as preferred under the loading in the same circumstances. This study aimed at measuring and comparing the stress induced in Filtek ™ Z350 XT (3M ESPE) composite, Tetric EvoCeram ® (ivoclar vivadent) composite and BRILLIANT ™ NG (Coltène/Whaledent) composite experimentally and numerically.Experimental analysis included cavity preparation in the Brass block with a concave (U - shape) cavity which represent a proximal cavity preparation. This cavity was used as a mold for sample preparation. The internal line and point angles of the cavity (mold) were rounded and the dimensions of the cavity (mold) were 10mm × 10mm × 10mm (Total height of the box × Width of the top side of box × Length of the top side of box). The internal diameter of “U” was 5 mm at the base of the box. The mold was used to prepare forty five samples, fifteen samples for each type of composite material. So, three groups were prepared : Group A filled with Filtek ™ Z350 XT composite material, Group B filled with Tetric EvoCeram ® composite material and Group C filled with BRILLIANT ™ NG composite material.Electrical strain gauge (Tokyo Sokki, Japan) was embedded in composite material horizontally at the same level in each sample. Static load of 50 N was applied perpendicular to the center of the occlusal surface of composite restoration in each sample testing. The strain gauge was connected to a Wheatstone bridge with a signal amplifier which measures the strain during load application and gives the amplified signal from (0 to 4.8 volt) to LabJack data acquisition where a stream software give the final values of strain with the aid of a scaled equation of voltage. Then, the von Mises stress (effective stress) was calculated by using equations. Numerical analysis was done by using ANSYS 16.1 - (2015) (finite element tool) software that was used to create the 3 - Dimensional models represented the same materials and dimensions used experimentally. The physical characteristics of the composite models were inserted in the software which included Elastic modulus and Poisson’s ratio (?). Analysis was selected in a finite element method according to boundary conditions. A mesh size and an element size were estimated during the study. The stresses were calculated at static load of 50 N with the ANSYS 16.1 - (2015) software.The data were analyzed statistically by One - way ANOVA test and Least Significant Difference (LSD) test. One - way ANOVA test and LSD test results showed that there was a highly significant difference (P<0.001) presented between groups A and B, groups A and C and between groups B and group C. The Stress induced in BRILLIANT ™ NG composite after load application was the lowest stress value followed by Tetric EvoCeram ® composite and followed by Filtek ™ Z350 XT composite which was the highest stress value experimentally and numerically.

التسرب المايكروي لنوعين من القشرة الخزفية بوجود وعدم وجود الحشوة الراتنجية تحت جهاز التحميل الدوري == Microleakage of Two Porcelain Laminate Veneers Materials With And Without Composite Filling Under Cyclic Loading

Author name: ياسر علي النقيب
Supervisor name: عمار عطا الله علي السعدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:
Abstract: Although investigators have evaluated the microleakage of porcelain laminate veneers, there is insufficient data regarding the durability of porcelain laminate veneers bonded to existing composite fillings. The aim of this study was to evaluate the microleakage of porcelain veneers restorations fabricated from two types of CAD/CAM ceramic blocks bonded to teeth with or without composite class V composite filling.Forty eight sound, crack - free human maxillary first premolar extracted for orthodontic reasons were selected for this study. Teeth were divided randomly into.2 main groups, which further divded into 2 groups (12 sample each). Group A1 : IPS e.max CAD veneers with standardized class V composite filling, Group A2 : IPS e.max CAD veneers, Group B1 : VITA Suprinity veneers with standardized class V composite filling, Group B2 VITA Suprinity veneers. The class V cavities was restored with nanofilled composite (Filtek™ Z350 XT, 3M ESPE). Standard veneer preparations were made using Ceramic veneer burs system (Keramikveneers. de, Komet). All the veneers were milled by CAD/CAM technology (CEREC MC XL, inLab SW 15, Sirona Dental Systems) Composite fillings (groups A1 and B1) were sandblasted with alumina oxide.Porcelain veneers were cemented in place using light - cured resin cement (Rely Veneer Cement, 3M ESPE), Then the specimens were stored at 37? in distilled water for 2 weeks. Then mechanical load cycling (50,000 load cycle of 49 N at 2.5 Hz) and thermocycling procedure (500 cycles of 5 - 55 Co with 20 sec dwell time) were done. The specimens’ crowns were immersed in 2% methylene blue dye for two days, then mounted in clear acrylic before sectioning with a 0.35 mm microtome. Microleakage percentage were recorded using stereomicroscope and ImageJ program. Results were checked for normality of distribution (Kolmogorov - Smirnov test and Shapiro - Wilk test), and were analyzed with twoway ANOVA and independent samples t - tests. Two way ANOVA shows the significant effect of type of ceramic restoration and the highly significant effect of composite filling, however, the interaction between the main factors was non - significant. The results showed that the lowest mean of microleakage percentage was recorded for group A2 (4.6058% ± 1.5091) which considered statistically significant compared to group B2 (6.105%±1.456), and statistically highly significant compared to group A1 (6.6075%±1.3259) while group B1 recorded the highest mean of microleakage percentage (7.3158%±1.38713). In conclusion, the type of ceramic restoration and the presence of class V filling both had significant effects on microleakage of porcelain veneers. IPS e.max CAD veneers had significantly lower microleakage percentages compared to VITA Suprinity veneers. The presence of class V composite filling within the cervical finishing line of porcelain veneers had a highly significant higher microleakage percentage compared to groups without composite filling.

احتمالية حدوث العيوب في عاج الجذر نتيجة لاستخدام انظمة مختلفة من مبارد النيكل تيتانيوم == The Incidence of dentinal root defects caused by different Nickel Titanium instruments

Author name: نور الدين علي سعيد
Supervisor name: ايمان محمد الزقة
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:
Abstract: يعد الاعداد الميكانيكي الاحيائي لقنوات الجذر احد الخطوات الرئيسية لتحقيق حشوة جذر ناجحة بسبب امكانية ازالة الاجسام البكتيرية والحطام المتراكم وتسهيل وضع حشوة الجذر داخل القنوات. الغرض من هذه الدراسة هو لملاحظة ومقارنة احتمالية حدوث العيوب في عاج الجذر نتي | Vertical root fracture and crack formation can be seen in root dentin during and after endodontic procedures. Vertical root fracture is one of the most frustrating complications of root canal treatment, which often results in tooth extraction. The aim of this in vitro study was to compare the effect of different Nickel Titanium instruments (ProTaper Universal, EndoSequence, ProTaper Next and RECIPROC) on the dentinal wall in term of dentinal defects.Seventy - five straight palatal roots of freshly extracted human maxillary first molars teeth were used in this study, the palatal roots were sectioned at 11 mm from the apex and wrapped with two layers of aluminum foil, then placed in the center of elastic silicon mold. Fifteen roots were left unprepared to serve as a negative control group, the remaining 60 roots were divided into 4 groups, each group contained 15 roots : • Group I was prepared by rotary ProTaper Universal system.• Group II was prepared by rotary EndoSequence system.• Group III was prepared by rotary ProTaper Next system.• Group IV was prepared by reciprocating RECIPROC system.All canals were prepared to MAF # 40. After each file size of the (rotary files) or after three pecking motion of the (reciprocating files), the file was removed from the canal and the canal was irrigated with 1 ml of 2% of sodium hypochlorite. All files were cleaned periodically to prevent clogging of flutes during instrumentation. The canal remained patent by insertion size 15 K - file.When the instrumentation was completed, the roots were then embedded in a clear acrylic resin blocks and each root was sectioned into three levels : apical, middle and coronal. All samples were examined from coronal direction under Stereomicroscope. The number and the type of dentinal defects were recorded and classified. The collected data was tabulated and subjected to statistical analysis using chi - square test.The EndoSequence group showed the lowest number of dentinal defects followed by ProTaper Next group and then ProTaper Universal group. The highest number of dentinal defects were observed in RECIPROC group. Chi - square test showed that there were highly significant differences among groups (P < 0.01). The results showed a non - significant difference between EndoSequence and Protaper Next group (p > 0.05), and a significant difference with ProTaper Universal group (P < 0.05) and a highly significant difference with RECIPROC group (P < 0.01). The ProTaper Next group showed a significant difference with ProTaper Universal group and a highly significant difference with RECIPROC groups. There was no significant difference between RECIPROC and ProTaper Universal groups.

قوة الدفع الرابطة الى الخارج والتسرب القمي للمواد (MTA Plus, Biodentine and Bioceramic) بتقنية حشوة ثلث القمي للجذر : دراسة مختبرية == Push - Out Bond Strength And Apical Microleakage of (Mta Plus, Biodentine, And Bioceramic)As Apical Third Filling (An In Vitro Study)

Author name: عبير علي عباس
Supervisor name: جمال عزيز مهدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:
Abstract: اجريت هده الدراسة المختبرية لتقيم قدرة ختم لثلاث مواد استعملت ( بتقنة حشوة ثلث القمي لقناة الجذر ) باستعمال اختبار قوة الربط الدفع الى الخارج ودراسة التسرب القمي.ستين جذر حلقي الاسنان العلوية ذو قناة مستقيمة ذات فتحة قمية مكتملة التكوين مختارة بعناية وفق | This study was conducted to evaluate the sealing ability of three materials used as apical third filling by using push - out bond strength test and apical microleakage study.Sixty straight palatal roots of freshly extracted maxillary first molars were selected. All teeth had mature apices, selected carefully according to specific criteria. The roots were instrumented using crown down technique with rotary Protaper universal system, instrumentation were done with 5ml of 2.5% sodium hypochlorite used as irrigation between files, 17% buffered solution of EDTA was used as final irrigant followed by 2.5% sodium hypochlorite then 10ml distilled water to remove any remnant of irrigant. Roots were randomly divided into three groups according to the filling materials used ( twenty roots for each group) : Group (1) : MTA Plus ( 4mm thickness) using as apical third filling. Group (2) : Biodentine (4mm thickness) using as apical third filling.Group (3) : Bioceramic root repair material (4mm thickness) using as apical third filling.Easy and Quick (E&Q) obturation system were used to complete obturation of roots. After incubation period at 37 °C for three days. Ten roots from each group were used for push - out test, after root were embedded in clear acrylic resin, sectioned at apical level in 2mm and 4mm from root apex to provide slice 2mm in thickness. The bond strength was measured using computerized universal testing machine, each section fixed in the machine so that the load applied from apical to coronal direction at 0.5mm/min speed and the computer drew curve to show the higher bond force before dislodgment of the filling material. These force were divided by surface area to obtain the bond strength in MPa.After debonding each sample was examined under Stereomicroscope and the type of failure mode was recorded. The result showed non significant different between Biodentine group and MTA Plus group. Biodentine group showed a very high significant difference with Bioceramic material group. Also high significant difference between MTA Plus group and Bioceramic material group. The Biodentine group showed highest mean of bond strength in comparison to other test group.Ten roots remain from each group used for apical microleakage study. The roots submerged in 2% methylene blue for three days. The roots were cleared and the degree of linear dye penetration was measured in millimeter by stereomicroscope under 40 X magnification with calibrated scale ocular grid. The result showed the Biodentine group lowest mean of microleakage than other group while Bioceramic material group showed high mean of microleakage than other groups. There are no significant difference among groups. There is positive correlation between push - out bond strength and an apical dye penetration in microleakage for each group of material.

قياس قوة الدفع للخارج لحشوات الجذور GuttaFlow 2 , Thermafil وGuttaCore : دراسة مختبرية == Push Out Bond Strength of Guttaflow 2, Thermafil, And Guttacore Obturation Materials (An In Vitro Study)

Author name: حيدر طالب فاضل
Supervisor name: جمال عزيز مهدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:
Abstract: اجريت هذه الدراسه المختبرية لقياس قوة ارتباط لثلاثه مواد مختلفة لحشوات قنوات الجذور باستخدام قوة الدفع للخارج.ثلاثون جذر حلقي مستقيم من الاسنان العلوية الخلفية استخدمت في هذه الدراسه وهذه الاسنان تم تحضيرها بتقنيه التاج السفلي باستخدام نظام المبارد الد | This in vitro study was carried out to investigate the push out bond strength of three different obturation materials GuttaFlow 2, Thermafil and GuttaCore at different levels.Thirty extracted upper molars were collected and the platal roots were sectioned at the CEJ of the tooth. The platal roots were instrumented with Hyflex CM rotary files to the size of 40/0.06.The instrumented samples were divided into three groups of ten samples each, the first group were obturated with GuttaFlow 2, the second group were obturated with Thermafil and the third group were obturated with GuttaCore obturating materials.After an incubation period of 7 days, each sample were sectioned into three sections of 2 mm thickness (apical, middle, coronal), each slice then introduced to the push out testing using a universal testing machine at a cross head speed of 0.5 mm/min. The result of this study showed Push - out bond strengths were significantly higher when canals were filled with GuttaCore than those filled with Thermafil and GuttaFlow 2. And Thermafil showed a higher significant difference than the GuttaFlow 2. It also showed that the bond strength values decreased from the coronal to the apical direction.In conclusion, the thermoplasticized gutta - percha appears to achieve higher push out bond strength values than the cold flowable gutta - percha. With GuttaCore showed higher push out bond values than Thermafil.

حدوث وشدة الالم بعد استخدام ثلاثة انظمة مختلفة لتحضير قنوات الجذور == Incidence And Severity of Pain Following The Usage of Three Different Root Canal Instrumentation Systems

Author name: احمد حمد عبيد
Supervisor name: جمال عزيز مهدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:
Abstract: Postoperative pain after endodontic procedures is an undesirable occurrence for both patients and clinicians. Certain factors may predispose to the development of postoperative pain. Knowledge of the causes and mechanisms behind interappointment pain in endodontics is of utmost importance for the clinician to properly prevent or manage this undesirable condition. The causative factors of interappointment pain encompass mechanical, chemical, and microbial injuries to the pulp or periradicular tissues, which are induced or exacerbated during root canal treatment. Ninety patients were recruited and included in this study out of one hundred and twenty patients, those patients requiring endodontic treatment on their permanent upper or lower molar teeth with asymptomatic irreversible pulpitis preoperatively, access opening and instrumentation was performed at the same visit.Patients ranged in age from 19 to 50 years old, and all were in good health, as determined from a written health history and oral interview.The patients were assigned randomly into three groups of 30 patients each : ? First group (n=30) : Teeth were instrumented using Universal ProTaper System (Full Rotary technique).? Second group (n=30) : Teeth were instrumented using ProTaper Next System (Full Rotary technique).? Third group (n=30) : Teeth were instrumented using WaveOne System (Reciprocating technique).Pain assessment carried out at day 1, 2, 3 & 7 using Verbal Rating Scale (4 - Point Scale). Patients recorded the incidence and severity of pain experienced.Patients were called at 24, 48 and 72 hours to obtain their reports for the first three days. Seven days after treatment their records were reviewed and percussion test was performed. Result showed that all groups induced Post - operative Pain, the difference is some systems cause more Post - Operative pain than other do : group 3 (WaveOne group) showed higher incidence and severity of PostoperativePain, followed by group 1 (Universal ProTaper group) that has shown less incidence and severity of Post - operative Pain than group 3 (WaveOne group), last group which it was group 2 (ProTaper Next group) has shown the lowest incidence and severity of Post - operative Pain. The data obtained were analyzed statistically using Chi Square test, total score for Verbal Rating Scale at day 1, 2, 3, and 7 showed that there was a highly significant differences between ProTaper Next group and other twogroups (P ? 0.001), and non - significant differences between ProTaper group and WaveOne group (P ? 0.05).

تاثير التصلب الضوئي للصمام الثنائبي لانبعاث الضوء على عمق التصلب والصلاة المجهرية لثلاثة انواع من حشوة المتراكمات بكمية كبيرة : دراسة مقارنة == the effect of LED light on depth of cure and microhardness of three types bulkfill composite : acomparative study

Author name: مهند رسول عبد الاخوة
Supervisor name: لمى محمد سليم بابان
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
University: University of Baghdad
Language: English
University location: Baghdad
First pages:

تقييم قابلية التنظيف للانظمة OneShape, ProTaper, Reciproc, WaveOne باستخدام التحليل المظهري للصورة الرقمية == Evaluation Of The Cleaning Efficiency Of Oneshape, Waveone, Reciproc And Protaper Systems Using Digital Image Morphometric Analysis

Author name: لمى عباس جسام
Supervisor name: حكمت عبد الرحيم الغراوي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

تقييم كمية الحطام المقذوف قميا خارج الجذر باستخدام انظمة مختلفة لتحضير قناة الجذر == Evaluation Of The Amount Of Apically Extruded Debris Using Different Root Canal Instrumentation Systems

Author name: هاشم معين حسين
Supervisor name: ايمان محمد الزقة
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

اختلال حافات الاغلفه المعدنية المصنعه من معدن الكروم كوبلت باستخدام ثلاث طرق مختلفة == Marginal Discrepancy Of Cobalt Chromium Metal Copings Fabricated With Three Different Techniques

Author name: ايناس اتحاد جليل
Supervisor name: عمار عطا الله علي السعدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

دراسة مخبرية لمقارنة الختم الذروي لثلاث تقنيات مختلفة من حشوات الاقنية == Comparison Of Apical Sealability Of Three Obturation Techniques : An In Vitro Study

Author name: منتظر سعودي كبة
Supervisor name: جمال عزيز مهدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

مقارنة التلائم الهامشي التطابق الداخلي والتسرب المايكروي للزولد الزركون الامبريس2 للتيجان الخزفية الكاملة : دراسة مخبرية == Comparison Of Marginal Adaptation, Internal Fitness And Microleakage Of Zolid, Zircon And Empress 2 All - Ceramic Crown Materials : An In Vitro Study

Author name: نصر رفعت سبع
Supervisor name: عمار عطا الله علي السعدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

التغييرات في اللون وخشونة سطح المينا بعد التبييض بالليزر الهجين باستخدام تراكيز مختلفة من بيروكسيد الهيدروجين : دراسة مختبرية == Color Change And Surface Roughness Of Enamel Following Hybrid Laser Bleaching With Different Hydrogen Peroxide Concentrations : An In Vitro Study

Author name: فادي متي ال حنو
Supervisor name: معن موفق نايف
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Mosul
First pages:

دفع الى الخارج القوة الرابطة لمواد مختلفة لحشوات جذور الاسنان == Push - Out Bond Strength Of Different Root Canal Obturation Materials

Author name: سندس حسين ناصر
Supervisor name: ايمان محمد الزقة
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

تقييم انتقال قناة الجذر وقابلية الحفاظ على تمركزها بمستويات مختلفة لقنوات جذور حضرت بواسطة المبرد ذو الضبط الذاتي باستخدام التصوير المقطعي : دراسة مقارنة == An Evaluation Of Canal Transportation And Centering Ability At Different Levels Of Root Canals Prepared By Self Adjusting File Using Computed Tomography : A Comparative Study

Author name: فرح صلاح الدين عباس
Supervisor name: حكمت عبد الرحيم الغراوي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

قدرة البقاء في مركز القناة وانتقال جدران القناة لادوات ProTaper, Mtwo, WaveOne, Reciproc في القنوات المقوسة المقلدة : دراسة مقارنة == Centering Ability And Canal Transportation Of ProTaper, Mtwo, WaveOne & Reciproc Files In Simulated Curved Canals : A Comparative Study

Author name: رفل محمد مريوش
Supervisor name: جمال عزيز مهدي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
Language: English
University location: Baghdad
First pages:

تقييم كمية الفلور المتحرر من مواد الاسنان التعويضيه المحررة للفلور وتاثيره على انتشار التسوس الثانوي المختبري == Evaluation Of Fluoride Release From Different Restorative Materials And Its Inhibitory Effect On Artificial Secondary Caries Extension

Author name: تارة سردار عبد الخالق القطب
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
University: University of Baghdad
Language: English
University location: Baghdad
First pages:

تقييم مدى تاثير المعالجات السطحية في ترميم الملغم السني : دراسة مختبريه == An Evaluation Of The Effect Of Surface Treatments On Amalgam Repair : In Vitro Study

Author name: بيداء محمد زيدان
Supervisor name: عبد الكريم جاسم العزاوي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
University: University of Baghdad
Language: English
University location: Baghdad
First pages:

مقارنة قوة الكسر لاربعة انواع من مواد الترصيعات السنية == A Comparison Of Four Types Inlay Materials Fracture Strength

Author name: وسام عادل نجم
Supervisor name: معن رشيد زكريا
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
University: University of Baghdad
Language: English
University location: Baghdad
First pages:

طريقة مبتكرة لازالة الشبكة الغروية من العاج السني المخرش حامضيا بواسطة استخدام ليزر النيودميوم : يتريوم المنيوم كارنت == A Novel Method For Removing Collagen Network From Acid Etched Dentin By Using Nd : YAG Laser

Author name: رعد نعمة دايم
Supervisor name: وليد نجم الهاشمي
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Doctorate
University: University of Baghdad
Language: English
University location: Baghdad
First pages:

تقييم تاثير كاشف التسوس الحامضي على قوة الربط القصي لنظامين من المواد التعويضية الرابطة : دراسة مختبرية == The Influence Of Caries Detector Dye On Shear Bond Strength Of Dentin Using Two Dentin Adhesive Systems : In Vitro Study

Author name: سلمى عيسى دهيم
Supervisor name: خلود سفر نجيب
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
University: University of Baghdad
Language: English
University location: Baghdad
First pages:

تاثير فترات التصلب وطرق التصلب الضوئي على معدل التاكل لراتنجات الكومبوزت المصلبة ضوئيا == The Effect Of Curing Times And Photoactivation Methods On The Wea Rate Of Light Activated Composite Resins : In Vitro Study

Author name: سحر سمير فتوحي نعوم
General topic: Dentistry
Specific topic: Dental Treatment
Degree: Master
University: University of Baghdad
Language: English
University location: Baghdad
First pages:
1 2 3 4 5 6