تحضير ودراسة خواص الفصل لطور ثابت جديد لتقنية HPLC == PREPARATION AND CHARACTERIZATION OF NEW HPLC STATIONARY PHASE

اسم المؤلف: هاجر سعد نجم
اسم المشرف: شهباز احمد مكي
الموضوع العام: علوم الفيزياء
السنة: 2011
الموضوع الدقيق: الفيزياء
الدرجة: ماجستير
اللغة: الانكليزية
مكان الجامعة: بغداد
الصفحات الاولى:
المستخلص: prepared by the reaction of congo red solution with amberlite anion exchange.SUMMaRYThe F.T.I.R elemental analyses have configured the attachment of congo red on the resin as has indicated by the physical appearance of the new resin.The resin capacities of newly prepared resin has calculated the resin capacity for the amberlite - congo red resin was found to average 7.36 meq/ gm and for the amberlite resin 3.0 meq./gm.The new stationary phase has been packed into stainless steel column. This has been done by the special technique. The chromatographic performance of the packed column was characterized the number of plate numbers, height equivalent of a theoretical plates(HETP) capacity factors, selectivity factor and peak asymmetry were measured by analyzing different analysis on the new column using different mobile phases composition and flow rates. The parameters were measured from analysis of some amino acids such as phenyl alanine, tyrosine and tryptophan. The analysis of amino acids using amberlite - congo red column has performed with an aqueous mobile phase adjusted at pH 10. The average number of plates, N was(111.09 - 284.3) . The plate height H was (0.01343) cm, capacity factor, ḱ were ranged from(3.5 - 3.76). and peak asymmetry value was1.06. The analysis of some amino acid of the some column but with a mobile phase adjusted at pH 10 with 20% aceto nitrile, the chromatographic parameters were plate’s number, N was(176.3307). plate height H was(0.128) cm, capacity factor Ќ were ranged from(2.98 - 4.65).

الفصل الكروموتوكرافي لبعض الاحماض الامينية بواسطة طريقة كروموتوكرافيا السائل العالية الاداء باستعمال طور ثابت جديد == Chromatographic Separation of Some Amino Acids by High Performance Liquid Chromatography Method Using A New Stationary Phase

اسم المؤلف: علي عباس رسول
الموضوع العام: علوم الكيمياء
السنة: 2011
الموضوع الدقيق: الكيمياء
الدرجة: ماجستير
اللغة: الانكليزية
مكان الجامعة: بغداد
الصفحات الاولى:
المستخلص: New stationary phase for high performance liquid chromatographyhas been prepared by the reaction of Neutral red solution with Weaklyacidic cation exchanger resin . The stability of the new attachedfunctional group on the resin was studied against different solvents suchas benzene, ethanol, acetonitrile, acetone, methanol, chloroform, andpetroleum ether as well as NaOH and HCl solutions. The new preparedresin was found stable and no depletion of the Neutral red moiety fromthe resin was noticed with the above materials .The FTIR analysis hasconfigured the attachment of Neutral red on the resin as well as thephysical appearance of the new resins.The new stationary phase has been packed into stainless steel column. The pKa value for new resins has been calculated. The pKa for Weakly acidic - Neutral red resins were 7.15. The chromatographic performance of the packed column was characterized. The number of plate numbers N, height equivalent of a theoretical plates H, capacity factors Ḱ, selectivity factors α, and peaks asymmetry, and Resolution RRsR were measured by analyzing different analytes on the new columns using different mobile phase compositions and flow rates.These parameters were measured from analysis of some amino acids such as Histidine, Phenylalanine, Tryptophan, and Tyrosine. The analysis of amino acids using Weakly acidic - Neutral red column has performed using %10 acetonitrile in buffer phosphate as mobile phase.The average value of plate numbers N was (316.59) . The plate heights H was averaged (0.085) cm , capacity factors Ḱ were ranged from (1.8 - 2.86). Separation factors α were ranged from (0.21 - 1.17), and peak asymmetry value were range from (0.99 - 1.09). Resolution RRsR were ranged from (0.93 - 3.77).IIThe analysis of amino acids using a new stationary phase has performed using buffer phosphate as mobile phase . The average value of plate numbers N was (234.79) , plate heights H was (0.107)cm , capacity factors Ḱ were ranged from (1.13 - 4.73) , separation factors α were ranged from (0.23 - 1.22) , peak asymmetry value were range from (1.10 - 1.18) and resolution were (0.93).R.S.D were ranged from(0.04 - 1)% , recovery were ranged from (93.8 - 97.12)% , The relative errors were ranged from ( - 2.88 - - 6.2) % .Calibration curves for all analyzed compound were linear from their detection limits to at least 50 ppm with correlation coefficient ranged from(0.9991 - 0.9996).The detection limits were ranged from(0.05 - 0.25) ppm at signal to noise ratio of three or more.

هرمونات الغدة الدرقية والكورتيزول والبرولاكتين ومؤشر كتلة الجسم لدى مرضى السكري من النوع الثاني == The Profile of Thyroid Hormones, Cortisol, Prolactin and Body Mass Index in Patients with Diabetes Type 2

اسم المؤلف: محمد صفاء شوكت النجار
اسم المشرف: سلمان علي احمد
الموضوع العام: علوم الكيمياء
السنة: 2011
الموضوع الدقيق: الكيمياء
الدرجة: ماجستير
اللغة: الانكليزية
مكان الجامعة: بغداد
الصفحات الاولى:
المستخلص: Diabetes is a group of disorders that produce elevated levels of blood glucose. The two main forms of diabetes are type 1and type 2. The cause of diabetes was associated with some endocrine hormones and obesity. This study was focused on diabetes type 2 and its effects on thyroid hormones (TSH, T3, T4), prolactin and cortisol and with body mass index. To achieve this aim 68 diabetic patients type 2 with ages of 35 - 70 years and 34 healthy people with ages of 35 - 70 years (control group) were enrolled. These hormones (TSH, T3, T4, PRL and Cortisol) were estimated by an enzyme immunoassay method with final fluorescent detection (MiniVidas).The results demonstrated significant increase of T4 (p<0.05), Cortisol (p<0.05) levels, and significant decrease of TSH (p<0.05) levels. A non significant increase was shown in prolactin (p>0.05) levels, and non significant decrease in T3 (p>0.05) levels.Obesity is the most important modifiable risk factor in the pathogenesis of type 2 diabetes, however, racial factors seem to be important in the relationship between body mass index and glucose in patients with diabetes type 2.The linear regression analysis revealed significant negative correlation (r= - 0.310, p<0.01) in cortisol levels with BMI, and significant positive correlation in fasting serum glucose (r=0.293, p<0.05) and TSH (r=0.275, p<0.05) levels with BMI in patients with diabetes type.The linear regression analysis revealed significant negative correlation (r= - 0.249, p<0.05) in cortisol levels with fasting serum glucose, and positive correlation in TSH (r=0.258, p<0.05) levels with fasting serum glucose in patients with diabetes type 2.The linear regression analysis revealed significant negative correlation (r= - 0.469, p<0.05) in T4 levels with Cortisol levels in patients with diabetes type 2.

عمود فصل جديد لتقنية الكروماتوكرافيا السائلة عالي الاداء (HPLC) == New column for high performance Liquid chromatography (HPLC)

اسم المؤلف: احمد مرزة حمزة
الموضوع العام: علوم الكيمياء
السنة: 2011
الموضوع الدقيق: الكيمياء
الدرجة: ماجستير
اللغة: الانكليزية
مكان الجامعة: بغداد
الصفحات الاولى:
المستخلص: New stationary phases for high performance liquid chromatography has been prepared by the reaction of Bromophenol blue salt solution with Amberlite CG - 400 (ClP P) resin . The stability of the new attached functional group on the resin was studied against different solvents such as benzene, ethanol, acetonitrile, acetone, methanol, chloroform, and petroleum ether as well as NaOH and HCl solutions. The new prepared resin was found stable and no depletion of the Bromophenol blue moity from the resin was noticed with the above materials .The FTIR analysis has configured the attachment of Bromophenol on the resin as well as the physical appearance of the new resins.The new stationary phase has been packed into stainless steel column.The resin capacity of newly prepared resin has calculated. The resin capacity for the Amberlite - bromophenol blue salt was found to average 5.27 meq./g which is more than the Amberlite resin, 3.95 meq./g.The chromatographic performance of the packed column was characterized. The number of plate numbers N, height equivalent of a theoretical plates H, capacity factors Ḱ, selectivity factors α, and peaks asymmetry, and Resolution RRsR were measured by analyzing different analytes on the new columns using different mobile phase compositions and flow rates.These parameters were measured from analysis of some amino acids such as Histidine, Phenylalanine, Tryptophane, and Tyrosine. The analysis of amino acids using Amberlite - Bromophenol blue column has performed using %10 acetonitrile in water as mobile phase.The average value of plate numbers N was192.085. The plate heights H was averaged 0.089 cm , capacity factors Ḱ were ranged from 1.8 - 2.42. Separation factors α were ranged from 0.86 - 1.3 , and peak asymmetry value were range from 1.02 - 1.98 . Resolution Rs were ranged from 0.92 - 4.15 . R.S.D were ranged from(0.06 - 0.10)% , recovery were ranged from (95.84 - 96.88)% , The relative errors were ranged from ( - 3.12 - - 4.64) % . Calibration curves for all analyzed compound were linear from their detection limits to at least 50 ppm with correlation coefficient ranged from 0.9989 - 0.9996. The detection limits were ranged from 0.05 - 0.25 ppm at signal to noise ratio of three or more.

تصنيع اقطاب انتقائية جديدة لتقدير كل من الكلور امفينيكول صوديوم ساكسينيت والحديد الثلاثي وتطبيقاتها في المستحضرات الصيدلانية == Construction of new Ion Selective electrodes for Determination Chloramphenicol sodium succinate and Iron(III) and their applications in pharmaceutical samples

اسم المؤلف: وئام رعد عزيز
اسم المشرف: خالدة حميد محمد السعيدي
الموضوع العام: علوم الكيمياء
السنة: 2011
الموضوع الدقيق: الكيمياء
الدرجة: ماجستير
اللغة: الانكليزية
مكان الجامعة: بغداد
الصفحات الاولى:
المستخلص: Two kinds of electrodes were prepared in this study based on PVCmatrix. Four ion selective electrodes for Chloramphenicol sodiumsuccinate which based on chloramphenicol palmitate (CPP) and sodiumtetraphenylborate (TPB) as additive, Another Four ion selectiveelectrodes for Iron(III) based on Chloramphenicol sodium succinate - Iron(III) [CPSS - Fe(III)] ion - pair complex as the electro - active material,.Many plasticizers used :  Di - butyl phthalate (DBPH) Di - butyl phosphate (DBP) Di - octyl phthalate (DOP) Tri - butyl phosphate (TBP)The electrodes parameters were include, linear concentration range,Nernestian slope, limit of detection, response time, life time, working pHrang and selectivity were evaluated. Also the statistical treatments wereapplied for the results that include : relative standard deviation (RSD),relative error (RE), error and confidence limit for concentration. The resultsshowed : 1 - ISES for Chloramphenicol sodium succinate : CPP+TPB+DBPH (membrane A1), CPP+TPB+DBP(membrane A2),CPP+TPB+DOP (membrane A3), CPP+TPB+TBP (membrane A4), givesthe slopes (53.98, 51.45, 49.66 and 48.98 mV/decade), linear range from(1x10 - 4 - 1x10 - 1, 5x10 - 4 - 1x10 - 1, 1x10 - 4 - 1x10 - 1, 5x10 - 4 - 1x10 - 1), withdetection limit (5x10 - 5M, 2x10 - 5 M, 3x10 - 5 M and 1x10 - 5 M), responsetime of 10 - 3M (15, 18, 20 and 35 second) and the lifetime were about (50,15, 23 and 21 day ). The working pH ranges were ranged from (2 - 7.5).The electrode A1 (CPP+TPB+DBPH) has been used to determineVIChloramphenicol sodium succinate in the pharmaceutical samples of(Chloramphenicol sodium succinate injection).2 - ISES for Iron(III) : CPSS - Fe(III)+DBP (membrane B1), CPSS - Fe(III)+DBPH (membraneB2), CPSS - Fe(III)+DOP (membrane B3) and CPSS - Fe(III)+TBP(membrane B4), gives the slopes (19.79, 26.60, 16.01 and 13.82), linearrange from (1x10 - 5 - 1x10 - 2 M, 1x10 - 5 - 1x10 - 2 M, 1x10 - 6 - 1x10 - 2 M and1x10 - 5 - 1x10 - 2 M), with detection limit (9×10 - 6 M, 7×10 - 5 M, 2×10 - 6 Mand 9×10 - 5 M), response time of 10 - 3 M (10, 35, 15, 35 and 30 second),lifetime were about (37, 41, 23 and 16 days). The working pH rangeswere ranged from (2 - 6) by using electrode (CPSS - Fe(III)+DBP), andthis electrode has been used to determine Iron(III) in the pharmaceuticalsamples of (Feroglobin Capsules).The selectivity coefficients (KpotA,B) of ISES have been studied for thefollowing interference ions (Na+, K+, Mn+2, Cu+2, Zn+2, Fe+3, Al+3,Chloramphenicol palmitate, folic acid , Sucrose and Gelatin) by usingseparate solution method and fixed interfering mixed method.The UV - spectrophotometric method which includes : - The derivative spectra, the first - derivative (1D) spectra for Chloramphenicol sodium succinate solutions (2 - 64 mg/L) in wavelength equal 258 nm with (r2=0.99925). The analytical methods results showed to be simple, rapid and with a good accuracy by comparing between FirstDerivative (1D) and direct method of Ion selective electrode by using Ftest.The results shown, that the Chloramphenicol sodium succinate can be determined by using Ion selective electrode method because the value of the (F) experimental less than the value of the (F) theoretical at 95% confidence limit. Since Fcalculated‹ Ftable, we oncluded that there is nosignificant difference in precision between two methods

بعض المتغيرات الكيميائية لتشخيص الاحتشاء الحاد للعضلة القلبية == Some Biochemical Parameters For Diagnosis Of Acute Myocardial Infarction

اسم المؤلف: ضرغام صادق جعفر
اسم المشرف: سلمان علي احمد
الموضوع العام: علوم الكيمياء
السنة: 2011
الموضوع الدقيق: الكيمياء الحياتية
الدرجة: ماجستير
اللغة: الانكليزية
مكان الجامعة: بغداد
الصفحات الاولى: