التقييم النسيجي والميكانيكي للتكامل العظمي لزرعات التتانيوم بعد تحرير تصميم الجزء المسنن من الزراعة او طلائها بمادة بذور الكتان : دراسة تجريبية على الارانب == Histological And Mechanical Evaluation of The Osseointegration of Titanium Implants By The Modification of Thread Design And/Or Coating With Flaxseed (An Experimental Study On Rabbits)
Author name:
مصطفى هادي جواد
Supervisor name:
عذراء يحيى الحجازي | نبيل كاظم عبد الصاحب
General topic:
Dentistry
Specific topic:
Oral Histology
Degree:
Master
University:
University of Baghdad
Language:
English
University location:
Baghdad
First pages:
20T384 - p.pdf
Abstract:
Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and hold a potential to increase the predictability of expedited implant therapy.Numerous surface modification approaches have been developed for all classes of dental implants to modulate biological responses and improve the osseointegration and primary stability. Hence, Implant threads should be designed to maximize the delivery of optimal favorable stresses while minimizing the amount of extreme adverse stresses to the bone implant interface. In addition, using of biomaterial coating of implant surface for the enhancement of bone formation has been achieved through the modulation of osteoblasts adhesion and spreading that induced better stability and more implant surface contact area.The aims of the study are : 1. Evaluation of titanium implant osseointegration by the modification of thread design and I or coating its surface by Flaxseed.2. Evaluate the new surface modification of titanium implant, histologically, mechanically and radiographically.Materials and methods : One hundred and twenty eight commercially pure titanium (CpTi) screws were implanted in rabbit tibiae. Implants were divided as follows : 1. Dual - threaded group (32 implants). 2. Single - threaded coated with grinded flaxseed group (32 implants).3. Single - threaded with central groove (32 implants).4. Single - threaded (control) group (32 implants).Histological, mechanical and radiographical analysis were performed for all implants after each healing periods (2,4,6 and 8) weeks.Results : 1. Dual - threaded implant illustrated the highest mean value in thread width and removal torque, and it showed mature bone at 8 weeks.2. Grooved implant illustrated close opposing threads. 3. Coated implant illustrated highest mean value in osteoblast cell count and showed a proliferating cartilage zone that later on degenerated and replaced by bone.Conclusion : The present results conclude that each modified implants shows a different benefits whether a modification of the implant surface mechanically (dual or grooved thread) or by coating the implants with Flaxseed.