Logo

المستودع الرقمي العراقي

Iraqi Digital Repository

المقارنة بين مؤشر اداء عضلة القلب بطريقة الدوبلر الموجي النابض مع مؤشر اداء عضلة القلب بطريقة الدوبلر النسيجي لصدى القلب لمرضى الاختلال الوظيفي الانقباضي للبطين الايسر == Comparison Between Pulsed - Wave Doppler Derived Myocardial Performance Index with Tissue - Doppler Tie index in patients with Left Ventricular Systolic Dysfunction

اسم المؤلف: اسيل اقبال سعيد
اسم المشرف: حسن علي الفرحان
الموضوع العام: الطب
السنة: 2015
الموضوع الدقيق: صدى القلب
الدرجة: دبلوم عالي
الجامعة: جامعة بغداد - كلية الطب
اللغة: الانكليزية
مكان الجامعة: بغداد
الصفحات الاولى: 📎 19T1322 - p.pdf
المستخلص: Background : MPI is one of the methods used to assess global cardiac function, the Calculation of MPI using TDI may have advantages over conventional left ventricle inflow/outflow tract pulsed - wave Doppler (PWD) method that might be due to heart rariability; for example, all of the data needed for TDI - MPI calculation can be derived from one single cardiac cycle, whereas with PWD at least two different cycles are needed. Thus, heart rate variability does not interfere with TDI - MPI.Aim : Myocardial performance index (MPI) is usually measured with pulsed wave Doppler (PWD). Our aim was to compare this method with TDI - MPI in patients with LV systolic dysfunction and to assess the degree of agreement between PWD and a method based on tissue Doppler imaging (TDI).Patients and methods : Sixty - five patients with LV systolic dysfunction EF by Simpson method (38.6 ± 5.8) and 35 control subjects (with normal LV systolic function and diastole) EF (67.6 ± 2.8) underwent measurement of time intervals and MPI with PWD and pulsed TDI at septal, lateral, anterior, inferior sides of mitral annulus.Results : The agreement was moderate between two methods {Agreement = 46.7% Repeatability (for alpha = 0.05) = 0.609 (NS)}.Receiver operating characteristic curves showed very high accuracy for both methods to discriminate patients with LV systolic dysfunction from healthy subjects; the optimal cutoff point was different and specific to each method : 0.44 for the conventional method and 0.56 for the TDI - MPI method.TDI - MPI values were higher than conventional MPI values in both groups (55% ± 1% vs 44% ± 3%, P < 0.001 in the healthy subjects; 88% ± 23% vs 61% ± 16%, P <0.001 in the patients with HF).Conclusion : We performed a study in healthy adults and in patients with congestive heart failure to investigate the clinical agreement between MPI measured conventionally and by PW - TD of the mitral annulus. We found moderate agreement between MPI measured by the conventional method and by TDI.Both methods had high diagnostic accuracy for detection of systolic dysfunction and TDI - MPI was more sensitive

مشاركة البيانات

Share Data

المستودع الرقمي العراقي

Iraqi Digital Repository

info@iqdr.iq

طُبع في: 2026-08-18 02:11