طريقة طيفية جديدة لتقدير ايونات النحاس II والحديد III باستخدام المركبات الدوائية الاموكسيسلين صوديوم والسيفيكزيم ثلاثي الهيدرات == New Spectrophotometric Method for the Determination of Cu(II) and Fe(III) using Drug Compounds(Amoxicillin - Sodium and Cefixime Trihydrate)
Author name:
علي سعدون ناجي دحام
Supervisor name:
عباس نور الشريفي
General topic:
Chemistry
Specific topic:
Chemistry
Degree:
Master
University:
University of Babylon - College Of Science
Language:
English
University location:
Babylon
Abstract:
This thesis consists of three methods : | Describes three simple and sensitive methods for the determination of copper (II), iron (III) ions and Cefixime trihydrate drug. | The first method based on determination of copper ion in aqueous so-lution, in its pure form, pharmaceutical preparations and in fungicide sam-ples, by oxidizing phenol group in Amoxicillin drug in oxidative coupling reactions, coupled of two molecules of Amoxicillin, these oxidized by cop-per (II) ion as oxidized agent in alkaline medium pH 11.5 to give a violet coloured product, soluble in water, has maximum absorption at wave-length (540) nm at 30 ᵒC. Beer's law was obeyed between (5-32) μg.ml-1, a molar absorptivity (5× 104) L.mol-1cm-1, Sandell's sensitivity (0.12)μg cm-2, the LOD was (0.29) μg.ml-1 , LOQ was (0.97) μg.ml-1. | The second method includes determination of iron (III) depends on reduced iron (III) to iron (II) by Cefixime trihydrate as reducing agent, the iron (II) react with three molecules bipyridyl to form red coloured product complex, soluble in distilled water in acidic medium PH 3.3 that has max-imum absorption at wavelength 520 nm. Beer's law was obeyed between (0.5-11) μg.ml-1, a molar absorptivity (1.02 × 104) L.mol-1.cm-1, Sandell's sensitivity (5.49 ×10-3) μg.cm-2, the LOD was (0.013) μg.ml-1, LOQ was (0.045) μg.ml-1. This method was applied successfully for the determina-tion of iron (III) in pure state and in pharmaceutical formulations (Tablets, Syrup), the analytical results were compared with the standard method was used for determination of iron (III), | The third method has been described a reversible determination of Cefixime trihydrate based on the same above second method, the iron (III) as oxidizing agent in acidic medium, under the same optimum conditions at wavelength (520) nm. Beer's law was obeyed between (1-18) μg.ml-1, a | molar absorptivity (5.55 × 103) L.mol-1.cm-1, Sandell's sensitivity (1.01×10-2) μg.cm-2, the LOD was (0.032) μg.ml-1, LOQ was (0.106) μg.ml-1. This method was applied successfully for the determination of (CEFI) in phar-maceutical formulations (Tablets and Syrup). | Evaluating the proposed methods results by using F and t- test. It was found that results experimental F and t value at 95% confidence level did not exceed the critical values. This means the proposed methods have no different significally in accuracy and precision with standard method. The effect of interference ions (Mn(II), Co(II), Ni(II), Zn(II), Ag(II), Hg(I), Cd(II), pb(II)) on copper(II), and iron(III) also has been studied.